23 April 2013: Version 5.04a3 Build 011 - main changes |
- Condensation Risk Analysis:
• Internal conditions can now be set separately from external conditions.
• Users can create and use their own climate data. Further details are given in
Technical note 2013/01.
|
| |
09 April 2013: Version 5.04a3 Build 010 - main changes |
- SAP 9.90:
• Range check error when attempting to select mechanical ventilation products is now resolved.
• The compliance check list now reports *no cylinder* for a community heating scheme where
there is no hot water cylinder within the dwelling.
- U-values:
• Vapour resistance values for Xtratherm products are now correctly listed as vapour
resistivity values.
|
| |
27 February 2013: Version 5.04a3 Build 009
- main changes |
- SAP 9.90:
• Corrects regulation date for Northern Ireland to F1 2012
• required for BRE assessors to lodge EPCs, following change in BRE lodgement system.
• Further information available here: http://forum.techlit.co.uk/viewtopic.php?f=5&t=229
|
| |
07 February 2013: Version 5.04a3 Build 008
- main changes |
- SAP 9.90:
• Resolves lodgement issues for Stroma Accreditted Assessors.
|
| |
31 January 2013: Version 5.04a3 Build 007 - main changes |
- SAP 9.90:
• Resolves an issue with combi-boiler losses.
|
| |
22 January 2013: Version 5.04a3 Build 006 - main changes |
- U-values/Condensation risk:
• to follow.
|
| |
10 January 2013: Version 5.04a3 Build 005 - main changes |
- SAP 9.90:
• Default air infiltration rate now set at 10 rather than 15 m3/m².h.
- U-values:
• Material database now visible for Australia.
|
| |
13 December 2012: Version 5.04a3 Build 004 - main changes |
- SAP 9.90:
• occasional overprinting on PEA address area resolved.
• party walls now listed on SAP reports even if they have U-value of zero.
• extra 50 m² of floor area now no longer appears with a new SAP calculation.
- U-values:
• resolves issue where linked bridging and an additional un-linked bridge gave an incorrect result.
• duplication of calculations with tapered layers now preserves the taper details.
• second bridge for SCI P312 calculation
- SAP 2012:
• issue with PV resolved.
|
| |
06 November 2012: Version 5.04a3 Build 003 - main changes |
- SAP 9.90:
Resolves Landmark created problem for lodging EPC's through BRE.
|
| |
Version 5.04a2 Build 001 & Versions 5.04a3 Build 001 - 002 - main changes |
- Internal development builds and not public release.
|
| |
31 October 2012: Version 5.04a1 Build 002 - main changes |
- SAP 9.90:
Resolves Landmark created problem for lodging EPC's through Stroma.
|
| |
30 October 2012: Version 5.04a1 Build 001 - main changes |
- SAP 9.90:
• NI approval for SAP 2009 in conjunction with Part F 2012 (Technical Booklet F1 2012).
• EPC database location problem resolved with extra backslash.
• Community heating with geothermal heat source no longer gives negative TER.
• Error on loading PCDF resolved.
- U-values:
• Mechanical fixings correction:
- the units for point thermal transmittance have been corrected to W/K.
- the use point thermal transmittance setting is now retained when a calculation
is duplicated.
- point thermal transmittance values now work correctly for light steel frame constructions.
• There is a new thermal mass report which shows the results of kappa-value calculations.
This can be accessed from Sections to print dialogue.
• The ground floor details box for basement wall and floor U-value calculations now has
the height box.
• The selection of items in the Sections to print dialogue is now retained, so there is no need to re-set the selection every time a print or PDF output is required.
- IES import:
• The error 'invalid typecast' which occurred when copying non-geometry details between
SAP 9.81 dwellings has been resolved.
- Payback module:
• The output graph and the figures now change according to the year selected in the year slider.
• An additional data field has been added for the proportion of electricity exported.
This allows for in-dwelling use and export to be set separately, enabling more complex
payback situations to be modeled.
• The panel degradation is now correctly set as the percentage reduction.
|
| |
06 August 2012: Version 5.03a2 Build 002 - main changes |
- SAP 9.90:
Resolves minor bugs.
|
| |
23 July 2012: Version 5.03a2 Build 001 - main changes |
- General:
New installer and ability to change location of data files. See Technical Note 2012/1 on Downloads page.
- U-values:
New Templates added. See Technical Note 2012/02 on Downloads page.
|
| |
30 April 2012: Version 5.03a1 Build 011 - main changes |
- SAP 9.90:
Resolves Landmark created problem for lodging EPC's through the BRE and other Accreditation organisations.
|
| |
18 April 2012: Version 5.03a1 Build 010 - main changes |
- SAP 9.90:
Resolves Landmark created problem for lodging EPC's through Stroma.
|
| |
06 March 2012: Version 5.03a1 Build 009 - main changes |
- SAP 9.70:
Resolves an issue with printing/creating PDFs.
- U-values:
Added option to enter mechanical fixings correction using the point thermal transmittance, instead of the approximate method from BS EN ISO 6946 Annex D.
Added PDF creation button to the toolbar, next to the print button.
Air space resistance data only included in output if the air space resistance calculator was used for the layer.
|
| |
01 March 2012: Version 5.03a1 Build 008 |
- Internal development build and not public release.
|
| |
18 February 2012: Version 5.03a1 Build 007 - main changes |
- SAP 9.90:
Corrected issue with DHW only community heating scheme with gas as a heat source, where TER worksheet showed different result to Compliance checklist and screen.
- U-values:
Added air layer resistance calculation to print outs.
Corrected low emissivity surface values for ground floor calculations.
- Payback module:
Added carbon dioxide saving to calculation outputs.
Added option to create PDF file of outputs.
|
| |
14 February 2012: Version 5.03a1 Build 006 - main changes |
- SAP 9.90:
Draft SAP 9.92 (SAP 2012) module available.
This implements the draft SAP 2012 specification for the SAP and DER calculation. It does not yet include the 2013 TER calculation.
New function to convert a SAP 9.90 to SAP 9.81, giving backward compatibility.
- U-values:
Introduces calculation templates which enables users to build up their own library of commonly used calculations and to use calculations prepared by construction product manufacturers.
Suspended beam and block ground floor calculations no longer has option for non-calculated deck resistance.
- Payback module:
PV calculation corrected to only use SAP 2009.
|
| |
10 February 2012: Version 5.03a1 Builds 004 & 005 |
- Internal development builds and not public releases.
|
| |
31 January 2012: Version 5.03a1 Build 003 - main changes |
- SAP 9.90:
Now reports cylinder size in checklist if heat pump PCDF values are over-ridden.
New function to convert a SAP 9.90 to SAP 9.81, giving backward compatibility.
- U-values:
Region setting to Middle East now gives U-value rather than R-value result.
Air space resistance calculator added. Addresses unvented air layers and voids, well-ventilated air layers and slightly ventilated air layers.
New function in File menu: import U-value calculation from another project. Makes it easier to re-use standard calculations.
Tapered insulation: now possible to override base thickness and lambda value for individual sectors.
|
| |
05 January 2012: Version 5.03a1 Build 002 - main changes |
- SAP 9.90:
Improved import of mechanical ventilation parameters from SAP 9.81 to 9.90.
File location removed from bottom of Scottish EPC.
Now possible to enter a second main heating system with heating fraction of zero, which can then be assigned to water heating.
Resolved occasional problem with EPC lodgement issue at draft approval stage.
- <VE> Import to SAP:
Import now works from <VE> 6.4 and goes directly to a SAP 9.90 calculation.
New option to copy non-geometry data to all SAP 9.90 dwellings in project.
- U-value:
Modification to cut-to-falls insulation layers to allow different base thicknesses of insulation.
R-value calculation for Australian regulations now included, with different values for heat flow inside to outside and outside to inside.
New option for variable layer calculations which enables the calculation to be converted to a standard calculation with a selected layer from the variable layer pane replacing the variable layer.
Well-ventilated cavity calculation to ISO 6946:2007 now included.
Resistance of unheated spaces ISO 6946:2007 method now added to Edit Construction dialogue.
DeltaUf correction now uses total unbridged resistance.
- Condensation risk analysis:
Climate data for Republic of Ireland added.
- Psi-value:
Alpha development version of a psi-value assistant for use with THERM added to software.
|
| |
13 October 2011: Version 5.03a1 Build 001 |
BRE approved version for producing EPC's in Scotland.
|
| |
30 September 2011: Version 5.02a1 Build 016 - main changes |
- Payback calculator:
JPA Designer now includes a payback calculator for PV and wind turbines.
This new module is currently free for registered users of the SAP modules.
- U-values:
Limit on number of bridged layers increased from 5 to 9 to allow calculation of multi-foils and other complex constructions.
Variable layer calculations now work correctly when an air gap correction is applied to the variable layer.
- SAP 9.90:
Code for Sustainable Homes report now available as an output, showing values for Ene1, Ene2 and Ene7
Zero carbon assessment now included.
Compliance report no longer applies the in-use factor to the SFP when testing efficiency.
Resolved occasional overprinting when large numbers of openings included.
- SAP 9.81:
Now possible to select 'as-built' for a dwelling with an assumed air permeability of 15 to produce an 'as-built' regulations checkist.
Corrected an issue where 9.81 calculations picked up the 9.90 fabric U-value after a 9.90 calculation had been opened.
|
| |
09 September 2011: Version 5.02a1 Build 015 - main changes |
- Overprinting problem fixed.
- Now includes a zero carbon home print out.
- Allows EPC's for Scotland to be printed out from JPA Designer.
|
| |
30 August 2011: Version 5.02a1 Build 014 - main changes |
- “Error finding SAP Version 9.9 dwelling” fixed.
|
| |
12 August 2011: Version 5.02a1 Build 013 - main changes |
- Postcode location conflict between North West England and South West Scotland fixed.
|
| |
03 August 2011: Version 5.02a1 Build 011 - main changes |
- Error message when lodging a V15 EPC from a SAP 9.81 calculation now correctly warns that it is not a SAP 9.90 calculation.
- Program no longer retains Product Characteristics Database settings when the primary heating is switched from a boiler to a heat pump with default efficiency.
- Now possible to specify the flue arrangement for boilers in the Product Characteristics Database which can have either open or room-sealed flues.
- Incorrect fail report on some mechanical ventilation systems resolved.
|
| |
12 July 2011: Version 5.02a1 Build 010 - main changes |
- Prevents EPC showing dollar sign instead of pound sign on 64 bit Windows 7 systems.
|
| |
23 June 2011: Version 5.02a1 Build 009 - main changes |
- It is now possible to set a ground floor as a party floor in the Dimensions tab. This allows the correct specification of ground floor flats or maisonettes with basement flats below.
- The compliance checklist now shows the dedicated solar volume instead of the effective solar volume.
- The compliance test for the efficiency of microCHP now uses HPER as a maximum rather than a minimum.
|
| |
| 16 June 2011: version 5.02a1 Build 008 - main changes |
- Resolved EPC lodgement issue with heating controls on community heating schemes.
- TER calculations in Scotland now use thermal mass parameter of proposed building.
- TER calculations for biomass heating systems in Scotland corrected to use package 5.
- Compliance check for microCHP systems now uses HPER figure rather than SEDBUK rating.
|
| |
| 16 June 2011: version 5.02a1 Build 007 - main changes |
- Amended reference on regulations checklist to on-peak electricity to off-peak.
- Northern Ireland EPC lodgement resolved.
|
| |
| 24 May 2011: version 5.02a1 Build 006 - main changes |
- Heat exchangers for community heating systems: the compliance check on insulation thickness has been removed, and thicknesses below 50 mm will no longer report a fail.
- Party wall U-values over 0.20 W/m2K will be correctly marked as a fail.
- Main SAP window will now only shows the values for those opaque elements which are present in the calculation: the listing now includes party walls.
|
| |
| 18 May 2011: version 5.02a1 Build 005 - main changes |
- Resolved access violation error as a record is being added to the database while issuing an EPC for a dwelling with user-entered boiler efficiency.
- Resolved error with boilers with integral flue gas heat recovery.
- Resolved BRE lodgement issue with flats.
|
| |
| 11 May 2011: version 5.02a1 Build 004 - main changes |
- Fixes issue with EPC lodgements through BRE.
- No longer allows switching between using gross and net areas once any building element data has been entered.
- Average room height now relabelled average storey height (avoids confusion as includes floor depth).
- Data accuracy now limited to two decimal places (BRE requirement).
- Water heating system no longer has any efficiency improvement for weather or enhanced load compensator.
- Items on the SAP 9.90 edit menu now go to the correct tabs following the re-ordering of the Ventilation tab.
- Occasional overprinting on final pages of SAP 2009 output corrected.
|